Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

KB 109 (ABAP): Multi-Client Functionality

Category: Information

Priority: Normal

Platform: ABAP

Version: 1 from 23.03.2021

Description

Extractors with Multi-Client Functionality (PowerConnect 6.07)

Though the PowerConnect ABAP agent installation process occurs in a non-technical client (technical clients include 000, 001, and 066), functionality exists to extract data from multiple clients. Below are the list of extractors that currently have the ability to extract data from multiple clients as of PowerConnect ABAP version 6.07:

  • AL08

  • ATRA_STATE

  • BD87_DYN

  • CDPOS

  • NRIV

  • ROLE_AUTH

  • RSUSR003

  • RSUSR200

  • SCC4

  • SCOT

  • SLG1

  • SM04

  • SM19

  • SMQ1

  • SMQ2

  • SMQR

  • SOST

  • SRAL

  • ST01_STATE

  • ST03_RFCC

  • ST03_RFCS

  • ST03_USRW

  • ST03_WEBC

  • ST03_WEBS

  • ST22

  • STAD

  • STAD3

  • STMS_ROUTE

  • SU01

  • SU53

  • SWEQUEUE

  • SWI1_LOG

  • SXMB_MONI

  • TREAD_DYN

  • WE02

  • SUIM (SP 6.07+)

Configuration of Multi-Client Functionality

There are a subset of extractors, which require additional configuration to enable the multi-client functionality. The list of extractors which require additional configuration are:

  • SLG1

  • SMQ1

  • SMQ2

  • SU01

  • WE02

  • BD87_DYN

  • CDPOS

To complete the configuration, please follow the following steps:

  • Log into the client where the PowerConnect application is installed. Execute the /n/bnwvs/main transaction.

  • Stop the PowerConnect batch jobs using the buttons below:

  • Confirm that the PowerConnect batch jobs have stopped. The PowerConnect administrative console will look like this:

  • Go to Administrator → Setup Metric → Metric Configuration

  • To enable multi-client extraction functionality, you will need to adjust the highlighted sections below based on the extractor you would like to adjust.

  • Adjust the highlighted sections below for the desired extractors by adding an “X” or a “*” value depending on the extractor. See below for how this should be configured for each extractor. Save.

  • Go back to the PowerConnect administrative console, and then restart the PowerConnect batch jobs using the buttons below.

  • Confirm the batch jobs have started by validating that the check boxes display as green as seen in the screenshot below.

  • No labels