Objective:

Upgrade to a newer PowerConnect release.

General Advice:

Please read these instructions carefully and give attention to every detail. Missing any single step could result in problems later on.

Prerequisites and Preparation

!Important notes:

Known Issues

Issue Title

Issue Description

Resolution

Obsolete Extractor Added to PowerConnect Configuration During BC Set Activation

During the BC set activation process, we have seen an obsolete version of the table reader extractor added to the PowerConnect administrative console when customers have performed an upgrade. This issue causes short dumps in the system where the application is installed.

  • Confirm with the PowerConnect team via support incident that the short dumps are being caused by the obsolete table reader extractor being added during the BC Set activation process by attaching the PowerConnect troubleshooting logs (reference KB 97 - Troubleshooting Information) to a support incident.

  • Once the issue has been confirmed, reference KB 118 - Remove PowerConnect Extractor, which outlines how to remove the obsolete extractor from the PowerConnect administrative console.

SPAM Stops with message Errors when Disassembling OCS Package

SPAM stops during early phase of patch application (DISASSMBLE STAGE) reporting

Phase DISASSEMBLE: Explanation of errors and warnings

With the error The OCS package SAPK-670XXXXXXX is not digitally signed

This error / warning can be ignored. Partner OCS packages are not signed, only SAP packages are signed.

1. Stopping running processes

Once started, please make sure to stop all running PowerConnect processes. This is important since otherwise errors or even short dumps may occur when changing software components while the program is running.

Afterwards the process status should look like that:

2. Install upgrade package via SAP Support Package Manager

Next step is to actually install the update package.

In case the screen below is shown, please press ‘Ignore’ button on the toolbar:

Import is finished now.

3. Activate BC Sets

4. Upload PowerConnect Roles (PowerConnect ABAP 7.X)

5. Post upgrade activities

5.1 Activate/deactivate extractors introduced in latest release

After first access to /bnwv/main tcode, dialog below will be shown:

Following options could be chosen:

5.2 Start Power Connect Jobs

In case number of Total unsent metrics is not 0 after transaction start, please remove all collected metrics, using the Goto->Troubleshooting->Truncate cluster functionality: